排查光模块故障原因,少不了这2条命令!

在使用光模块的时候,你是不是也常常遇到各种各样的故障问题?像光模块型号选用是否正确、使用的跳线是否正确?虽然解决方案咱有,但遇到传输异常等问题时,好多人都不知道要如何排查、解决。今天这篇就教你用命令排查光模块故障!以及,为了减少光模块在使用中故障发生的概率,还是得用性能可靠稳定且品质有保障的光模块啊。当然,正确专业的操作方式也少不了。

01光模块故障定位常用命令

根据光模块的告警信息查找故障原因:

display interface transceiver

查看光模块光功率是否正常:

display interface transceiver verbose

02根据光模块的告警信息查找故障原因

执行命令display interface transceiver查看“Alarm information”下光模块是否有告警信息。

<HUAWEI> display interface 10ge 1/0/1 transceiver

 10GE1/0/1 transceiver information:
-------------------------------------------------------------------
 Common information:
   Transceiver Type                      :10GBASE_SR
   Connector Type                        :LC
   Wavelength (nm)                       :850
   Transfer Distance (m)                 :30(62.5um/125um OM1)
                                          80(50um/125um OM2)
                                          300(50um/125um OM3)
                                          400(50um/125um OM4)
   Digital Diagnostic Monitoring         :YES
   Vendor Name                           :HUAWEI
   Vendor Part Number                    :02318169
   Ordering Name                         :
-------------------------------------------------------------------
 Manufacture information:
   Manu. Serial Number                   :AQG269Y
   Manufacturing Date                    :2013-10-20
   Vendor Name                           :HUAWEI
-------------------------------------------------------------------
 Alarm information:
-------------------------------------------------------------------

如果出现LOS Alarm告警,则说明对端没有信号发送过来,在接口模式下执行命令display this查看两端端口是否shutdown,如果端口shutdown了,则执行undo shutdown操作。

03查看光模块光功率是否正常

执行display interface transceiver verbose命令查看光模块发送或接收光功率方面的信息,与光模块的标称光功率进行对比判断。

光模块的诊断信息中,可以查看当前发送和接收的光功率值,以及默认的最高和最低功率值。

<HUAWEI> display interface 10ge 1/0/1 transceiver verbose

 10GE1/0/1 transceiver information:
-------------------------------------------------------------------
 Common information:
   Transceiver Type                      :10GBASE_SR
   Connector Type                        :LC
   Wavelength (nm)                       :850
   Transfer Distance (m)                 :30(62.5um/125um OM1)
                                          80(50um/125um OM2)
                                          300(50um/125um OM3)
                                          400(50um/125um OM4)
   Digital Diagnostic Monitoring         :YES
   Vendor Name                           :HUAWEI
   Vendor Part Number                    :02318169
   Ordering Name                         :
-------------------------------------------------------------------
 Manufacture information:
   Manu. Serial Number                   :AQG269Y
   Manufacturing Date                    :2013-10-20
   Vendor Name                           :HUAWEI
-------------------------------------------------------------------
 Alarm information:
-------------------------------------------------------------------
 Diagnostic information:
   Temperature (Celsius)                 :33.68
   Voltage (V)                           :3.29
   Bias Current (mA)                     :7.97
   Bias High Threshold (mA)              :13.20
   Bias Low Threshold (mA)               :4.00
   Current RX Power (dBm)                :-2.15
   Default RX Power High Threshold (dBm) :1.00
   Default RX Power Low Threshold (dBm)  :-11.90
   Current TX Power (dBm)                :-2.07
   Default TX Power High Threshold (dBm) :1.00
   Default TX Power Low Threshold (dBm)  :-9.30
------------------------------------------------------------------

1、如果接收功率低(Current RX Power < Default RX Power Low Threshold),说明本端接收到的信号过低;则可能出现端口不UP或者UP后报文收发有丢弃,此时请先排查传输距离是否过远,超出了该光模块的传输距离,再排查光模块、光纤是否有损坏。

2、如果接收功率高(Current RX Power > Default RX Power High Threshold),说明本端接收到的信号过高;可能原因是该光模块为长距光模块,而实际传输距离太短,导致信号未衰减,此时应在光模块上增加光衰,以对光模块进行保护。

3、如果发送功率低(Current TX Power < Default TX Power Low Threshold),说明该光模块发送信号不好或光模块本身故障;可能会导致对端接收功率低,而造成端口不UP或者UP后报文收发有丢弃,请与技术支持人员联系。

4、如果发送功率高(Current TX Power > Default TX Power High Threshold),说明该光模块发送信号太强;可能会导致对端接收功率高,而造成对端光模块因接收功率持续过高而烧坏,可能原因是本端光模块故障,建议更换光模块。因此,在端口插入光模块并对接成功后,要对发送或接收光功率方面的告警信息进行排查,避免因功率过低或者过高造成流量或者光模块不正常。